  Datasheet File OCR Text:
  specifications are subject to change without notice (27.10.99) 1 panel meters and controllers panel meter modular series edm 35 ? modular digital panel meter, 3 1/2-digit ? indicating or controlling current, voltage, resistance, temperature, tacho or frequency. ? easy programming ? programmable hysteresis and time delay (up to 2 setpoints) ? data hold ? peak/valley function ? password protection of programming parameters ? stock-saving - several ranges on each input module ? ip 65 (front) ? optional hardware lock of programming ? optional high-efficiency red or green display product description ordering key main unit range power supply relay output signal output options the edm 35 is a 3 1/2-digit, modular digital panel meter where input and output mo- dules can be combined to suit many applications. scaling and setpoints are fully pro- grammable and the program- ming itself is very user-friend- ly. furthermore, the edm 35 includes peak/valley function and password protection. the housing is easy to mount and ensures a protection degree of ip 65. type selection range dc voltmeters: v1d: -199.9 to +199.9 mv v2d: -1.999 to +1.999 v v3d: -19.99 to +19.99 v v4d: -199.9 to +199.9 v v5d: -600 to +600 v * range ac voltmeters: v1a: 0 to 199.9 mv v2a: 0 to 1.999 v v3a: 0 to 19.99 v v4a: 0 to 199.9 v v5a: 0 to 600 v * range ohmmeters: r1d: 0 to 199.9 r2d: 0 to 1.999 k r3d: 0 to 19.99 k r4d: 0 to 199.9 k * nominal voltage according to iec 60664-1. the measuring range includes 15% tolerance equal to 690 v. range dc ammeters: a1d: -199.9 to +199.9 a a2d: -1.999 to +1.999 ma a3d: -19.99 to +19.99 ma a4d: -199.9 to +199.9 ma a5d: -1999 to +1999 ma a6d: -5.00 to +5.00 a a7d: -10.00 to +10.00 a range ac ammeters: a1a: 0 to 199.9 a a2a: 0 to 1.999 ma a3a: 0 to 19.99 ma a4a: 0 to 199.9 ma a5a: 0 to 1999 ma a6a: 0 to 5.00 a a7a: 0 to 10.00 a range thermometers: pt 100: p1c: -100.0 to 199.9c p2c: -100 to 850c p1f: -148.0 to 199.9f p2f: -148 to 392f p3f: -148 to 1562f thermocouple type j: -jc: -100 to 760c -jf: -148 to 1400f thermocouple type k: -kc: -100 to 1250c -kf: -148 to 1999f power supply: 3: 12 to 48 vdc 4: 230 vac 5: 115 vac 6: 48 vac 7: 24 vac relay output: 0: none 1: 1 relay 2: 2 relays signal output: x: none 1: 4 to 20 ma 2: 0 to 20 ma 4: 0 to 10 v 5: transducer power supply 12 vdc 6: transducer power supply 24 vdc contact factory for other out- put signals options: xx: none cx: high eff. red display dx: green display xp: program lock 01-99: special options (assigned by factory) edm35v1d41xxx range frequency meters: f1x*: 5.0 to199.9 hz f2x*: 10.0 to 1999 hz * replace x with: a for namur input b for npn, pnp & contact input c 600 vac input
2 specifications are subject to change without notice (27.10.99) series edm 35 separate ordering numbers main unit ordering number (mechanical parts included) red display (standard red) 5100511 red display (high-bright red) 5100512 green display 5100510 with program input modules lock vdc 5100530 5100630 vac 5100531 5100631 adc 5100532 5100632 aac 5100533 5100633 aac/adc 10 a 5100534 5100634 ohm 5100535 5100635 pt 100 5100536 5100636 pt 100 850c 5100539 5100639 thermocouple type j 5100537 5100637 thermocouple type k 5100538 5100638 tachometer 5100540 5100640 frequency meter 5100541 5100641 output modules 1 relay 5100561 2 relays 5100562 analog output 5100560 12/24 vdc excitation output 5100526 power supply modules 12 to 48 vdc 5100524 24 vac 5100523 48 vac 5100522 115 vac 5100521 230 vac 5100520 display 7-segment led, height 14.2 mm 2 leds for indication of relay on min./max. indication -1999/1999 overrange indication ee (underrange: -ee) accuracy see module specifications temperature drift see module specifications scaling electrical input range progr. within whole range display range progr. within whole range decimal point position programmable module connection screw terminals environment degree of protection ip 65 (front) ip 20 (behind panel) operating temperature 0 to +50c. r.h. < 90% non-condensing storage temperature -10 to +60c. r.h. < 90% non-condensing weight approx. 350 g depends on modules used housing dimensions 48 x 96 x 89 mm housing material abs/polycarbonate blend front material polycarbonate colour black housing red front with red display grey front with green display approvals ul, csa, sev general specifications supply specifications power supply ac overvoltage cat. iii (iec 60664) rated operational voltage 230 vac 10% 115 vac 10% 48 vac 10% 24 vac 10% frequency 50/60 hz 5hz voltage interruption 20 ms rated insulation voltage 250 vac basic rms rated impulse withstand voltage 6 kv (1.2/50 s) iec 60664-1 power supply dc rated operational voltage 12 to 48 vdc 15% voltage interruption 10 ms (voltage = 10 vdc) rated insulation voltage 150 vdc basic rated impulse withstand voltage 4.0 kv (1.2/50 s) iec 60664-1 rated operational power < 7 va emc electromagnetic compatibility immunity acc. to iec 60801-4 acc. to iec 60801-5 input specifications - general power supply input modules supplied by main unit emc electromagnetic compatibility immunity acc. to iec 60801-4 acc. to iec 60801-5 type selection (cont.) range tachometers: t1x*: 8.0 to 199.9 rpm @30 ppr** t2x*: 5.0 to 199.9 rpm @60 ppr** t3x*: 2.0 to 199.9 rpm @100 ppr** t4x*: 20 to 1999 rpm @30 ppr** t5x*: 10 to 1999 rpm @60 ppr** t6x*: 10 to 1999 rpm @100 ppr** * replace x with: a for namur input b for npn, pnp & contact input ** pulses per revolution
specifications are subject to change without notice (27.10.99) 3 series edm 35 input specifications - modules voltmeters - ac/dc (5100531/5100530, 5100631/5100630) thermometers (5100536/5100537/5100538, 5100539/5100636/5100637/5100638/5100639) range reso- accuracy temperature lution drift pt 100: -100.0 to 199.9c 0.1c 0.2% of reading 150 ppm/c 2 dgt 0.05 dgt/c -148.0 to 199.9f 0.2f 0.2% of reading 180 ppm/f 4 dgt 0.10 dgt/f -148 to 392f 1f 0.2% of reading 180 ppm/f 4 dgt 0.10 dgt/f pt100, 850c: -100 to 850c 1c 0.2% of reading 150 ppm/c 3 dgt 0.05 dgt/c -148 to 1562f 2f 0.4% of reading 180 ppm/f 6 dgt 0.1 dgt/f thermocouple type j: -100 to 760c 1c 0.1% of reading 100 ppm/c 4 dgt 0.05 dgt/c -148 to 1400f 1f 0.1% of reading 180 ppm/f 8 dgt 0.1 dgt/f thermocouple type k: -100 to 1250c 1c 3% of reading 100 ppm/c 3 dgt 0.05 dgt/c -100 to -50c 1c 1% of reading 100 ppm/c + 5/-1 dgt 0.05 dgt/c -50 to 780c 1c 0.1% of reading 100 ppm/c 3 dgt 0.05 dgt/c 780 to 1250c 1c 0.25% of reading 100 ppm/c + 1/-3 dgt 0.05 dgt/c -148 to 1999f 2f 3% of reading 180 ppm/f 6 dgt 0.1 dgt/f -148 to -58f 2f 1% of reading 180 ppm/f + 10/-2 dgt 0.1 dgt/f -58 to 1436f 2f 0.1% of reading 180 ppm/f 6 dgt 0.1 dgt/f 1436 to 1999f 2f 0.25% of reading 180 ppm/f +2/-6 dgt 0.1 dgt/f * nominal voltage according to iec 664-1. the measuring range includes 15% tolerance equal to 690 v. measuring jumper range code resolution input ranges position imped. ac dc 199.9 mv 1 - 4 7 1 0.1 mv 100 k 1.999 v 2 - 5 8 2 1 mv 100 k 19.99 v 2 - 5 9 3 10 mv 1 m 199.9 v 3 - 6 10 4 0.1 v 1 m 600 v * 5 - 6 12 6 1 v 1 m accuracy ac voltmeter 0.3% of reading 3 dgt dc voltmeter 0.2 % of reading 2 dgt temperature drift ac voltmeter 150 ppm/c 0.2 dgt/c dc voltmeter 100 ppm/c 0.05 dgt/c ammeters - ac/dc(5100533/5100532/ 5100534, 5100633/5100632/5100634) measuring jumper range resolution ranges position code ac dc 199.9 a 1 - 2 7 1 0.1 a 1.999 ma 2 - 3 8 2 1 a 19.99 ma 4 - 5 9 3 10 a 199.9 ma 5 - 6 10 4 0.1 ma 1999 ma 2 - 5 11 5 1 ma 5.00 a 2 - 5 12 6 10 ma 10 aac 2 - 3 12 - 10 ma 10 adc 1 - 2 - 6 10 ma accuracy ac ammeter 0.3% of reading 3 dgt ac ammeter (10 a) 0.5% of reading 5 dgt dc ammeter 0.2 % of reading 2 dgt dc ammeter (10 a) 0.5% of reading 5 dgt temperature drift ac ammeter 150 ppm/c 0.5 dgt/c ac ammeter (2 a, 5 a) 200 ppm/c 0.1 dgt/c ac ammeter (10 a) 200 ppm/c 0.5 dgt/c dc ammeter 100 ppm/c 0.05 dgt/c dc ammeter (2 a, 5 a) 200 ppm/c 0.5 dgt/c dc ammeter (10 a) 200 ppm/c 0.5 dgt/c voltage drop < 200 mv (all ranges) measuring jumper range- resolution ranges position code 199.9 1 - 4 7 0.1 1.999 k 2 - 5 8 1 19.99 k 3 - 6 9 0.01 k 199.9 k 1 - 2 10 0.1 k ohmmeters (5100535, 5100635) accuracy 0.2% of reading 2 dgt temperature drift 150 ppm/c 0.1 dgt/c
4 specifications are subject to change without notice (27.10.99) output specifications analogue output (5100560) measuring load ranges resistance 0 to 20 ma 500 4 to 20 ma 500 0 to 10 v 3 1,000 accuracy 0 to 20 ma 1% of reading 0.1 ma 4 to 20 ma 1% of reading 0.1 ma 0 to 10 v 1% of reading 0.05 v temperature drift 200 ppm/c short-circuit protection yes series edm 35 relay output 1 or 2 relays (5100561/5100562) power supply supplied by main unit output 1 or 2 spdt relays rated insulation voltage 250 v basic rms contact ratings (agcdo) resistive ac 1 5 a, 250 vac dc 1 5 a, 24 vdc small inductive loads ac 15 2 a, 250 vac dc 13 3 a, 24 vdc mechanical life 3 40 x 10 6 operations electrical life 3 10 5 operations (at max. load) operating frequency max. 10 hz (50% duty cycle) dielectric strength dielectric voltage 2 kvac (rms) rated impulse withstand volt. 4 kv (1.2/50 s) excitation output (5100526) power supply supplied by main unit output voltage 12 vdc: jumper position 3 - 6, tolerance 20% 24 vdc: jumper position 1 - 4, tolerance 20% output current 12 vdc 35 ma dc 24 vdc 20 ma dc emc electromagnetic compatibility immunity acc. to iec 60801-4 acc. to iec 60801-5 frequency meters (5100541, 5100641) measuring jumper range resolution ranges position code 199.9 rpm @30 ppr* j4, 1-2 7 0.1 rpm 199.9 rpm @60 ppr* j5, 1-2 8 0.1 rpm 199.9 rpm @100 ppr* j6. 1-2 9 0.1 rpm 1999 rpm @30 ppr* j4, 2-3 10 1 rpm 1999 rpm @60 ppr* j5, 2-3 11 1 rpm 1999 rpm @100 ppr* j6, 2-3 12 1 rpm * pulses per revolution tachometers (5100540, 5100640) input selection namur j1 npn, pnp, contact j2 accuracy 1% of reading 5 dgt temperature drift 200 ppm/c input impedance namur 1 k npn, pnp and contact 5 k time constant (tc) 1 sec. input specifications - modules (cont.) measuring jumper range resolution ranges position code 199.9 hz j7 7 0.1 hz 1999 hz j8 8 1 hz input selection namur j1, j4 and j6 npn, pnp, contact j2 and j5 600 vac j3 accuracy 1% of reading 5 dgt temperature drift 200 ppm/c input impedance namur 1 k npn, pnp and contact 5 k 600 vac 600 k time constant (tc) 1 sec.
specifications are subject to change without notice (27.10.99) 5 series edm 35 *) power supply 5100520-23 5100526 *) *) 5100561 *) 5100560 *) 5100530 5100562 *) wiring diagrams 5100531 *) 5100532 5100533 5100524 5100534 5100535 5100537 5100538 caution! since the input circuitry is not galvanically isolated, the po- tential of the measured varia- ble will be present on all con- nections to the unit (i.e. "hold" input). this is of speci- al importance when measu- ring line voltage and current. modules with type nos. xxxx63x are equipped with program lock function. *) module position (slot) in the base unit is indicated by a drawing on the plas- tic cover. note. by short-circuiting terminals marked "hold" (supply mod- ule), it is possible to hold the displayed value indefinitely (hold function). the compari- son of the input variable with the alarm setpoint remains active. to reactivate the dis- play, remove the short-circuit. 5100536 *) *) *) *) *) *) *) *) 5100540 *) 5100541 *)
6 specifications are subject to change without notice (27.10.99) operation diagrams setpoint operation scaling operation series edm 35 front panel description 1 1. keyboard ? s ? set/enter ? ? up ? ? down 2. display 3 1/2-digit (maximum read-out 1999). alphanumeric indication by means of 7-segment display for: - displaying of the measured value. - indication of programming parameters. 3. led - 1 and 2 led indicators for alarm conditions. 4. engineering unit screen for interchangeable unit label.the symbols in the greyish areas are those available on the set of engineering unit labels supplied with the edm. (engineering unit label to be inserted by customer.) set-up and programming procedures are easily controlled by the three pushbuttons. set/enter key: - entry of variables. - selecting programming functions. up and down key for: - display control. - increasing or decreasing programming value. - selecting programming functions and instrument configuration together with the ? s ? key. w = 08 m = 16 % = 24 mm hg = 32 cm = 40 mv = 01 kw = 09 hz = 17 mbar = 25 l/min = 33 m = 41 v = 02 mw = 10 khz = 18 bar = 26 l/h = 34 kg = 42 kv = 03 var = 11 rpm = 19 psi = 27 kg/min = 35 ppm = 43 a = 04 kvar = 12 m/s = 20 ata = 28 ton/h = 36 ka = 44 ma = 05 mvar = 13 m/min = 21 ate = 29 m 2 /min = 37 cos f = 45 a = 06 = 14 c = 22 kg/cm 2 = 30 m 2 /h = 38 m 3 = 46 mw = 07 k = 15 f = 23 mm h 2 o = 31 mm = 39 s = 47 3 2 4
specifications are subject to change without notice (27.10.99) 7 top view panel cutout panel all dimensions in mm. mode of operation the input range and the dis- play range are fully program- mable, and so are the set- point(s) if a relay output mo- dule is inserted. a hold func- tion is available for freezing a measured value. passwords 0 to 99 are for overall program- ming while passwords 100 to 199 allow direct set-point pro- gramming outside the pas- sword protection. see user manual for further details. settings programmable setting: see user manual. jumper setting: see user manual. depending upon the input modules used, it is possible to measure ac/dc (current or voltage), resistance (the range is selected with a jumper on the input module) or tempe- rature (pt 100 or thermocou- ple j/k). without an output module, the edm is an in- dicator - by inserting an out- put module the edm is a con- troller. overall dimensions and panel cutout front view side view modules and slot position rear view of main unit slot slot slot slot slot #1 #2 #3 #4 #5 input module: vac vdc aac adc 10a ac/dc pt 100 thermo couple tachometer frequency output module: excitation output analogue output power supply module: 24 vac 48 vac 115 vac 230 vac 12-48 vdc output module: 1 relay output 2 relay outputs series edm 35


▲Up To Search▲   

 
Price & Availability of EDM35VXXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X